FSC 7025 Information Technology Input/Output and Storage Devices

MFG SKUNSNItem NameDetailsCAGE CodeRFQ
CISCO 1003
CISCO1003
7025-01-500-5631Interface unit, Automatic Data PrPower Source: External
0GX96
CISCO 1605R
CISCO1605R
7025-01-484-0361Interface unit, Automatic Data PrSpecial Features: Dual ethernet with wan interface card slot router
III Part Name Assigned By Controlling Agency: Router with ip software
Power Source: External
0GX96
CISCO 1841
CISCO1841
7025-01-530-9889Interface unit, Automatic Data PrEND Item Identification: TDLS
Part Name Assigned BY Controlling Agency: Integrated services router
Power Source: External
0GX96
CISCO 2503
CISCO2503
7025-01-409-0586Interface unit, Automatic Data PrPower Source: External
Frequency in Hertz: 50.0 and 60.0
Alternating Current Voltage Rating in Volts: 110.0 and 220.0
0GX96
CISCO 2509
CISCO2509
7025-01-453-4797Interface unit, Automatic Data PrSpecial Features: Access servers for remote node and asynchronous/synchronous routing; 1 ethernet, 2 serial, 8 async serial, ac power supply
0GX96
CISCO 2511
CISCO2511
7025-01-453-6455Interface unit, Automatic Data PrSpecial Features: 1 ethernet, 2 serial, 16 async seial, ac power supply
Power Source: External
Frequency in Hertz: 60.0
0GX96
CISCO 2610XM
CISCO2610XM
7025-01-515-7052Interface unit, Automatic Data PrSpecial Features: Multi-service 10/100 ethernet router
0GX96
CISCO 2613
CISCO2613
7025-01-508-1966Interface unit, Automatic Data PrIII Part Name Assigned By Controlling Agency: Cisco 2612 router
0GX96
CISCO 2620
CISCO2620
7025-01-470-4564Interface unit, Automatic Data PrSpecial Features: Modular access router; multiservice voice/data integration; virtual private network access W/firewall options; analog and digital dial access services; routing W/bandwidth management; inter-vlan routing; one autosensing 10/100 mbps ethernet port; includes two wan interface card slots, a network module slot, and an internal advanced integration module slot
0GX96
CISCO 2620XM
CISCO2620XM
7025-01-506-6026Interface unit, Automatic Data PrSpecial Features: Multi-service 10/100 ethernet router; 50MHZ motorola power quicc MPC860P processor type; 30KPPS performance; 16MB/48MB flash memory; 32MB/128MB system memory slots; 1X network module; 2X wan I/face card; 1 X onboard aim slot; 1 X console, 1 X aux, 1X 10/100 fe onboard lan ports; integrated switches
0GX96
CISCO 2745
CISCO2745
7025-01-523-3029Interface unit, Automatic Data PrIII End Item Identification: Traffic management advisor (tfmictas) (tma)
III Part Name Assigned By Controlling Agency: Router; model 3745
0GX96
CISCO 2811 ROUTER
CISCO2811ROUTER
7025-01-546-1694Interface unit, Automatic Data PrSpecial Features: Dram 256 mb default, 768 max;compact flash 64 mb default 256 mb MAX;2 us ports 1.1, 4 interface card slots
III Part Name Assigned By Controlling Agency: Integrated service router
Power Source: External
0GX96
CISCO 2821
CISCO2821
7025-01-538-0875Interface unit, Automatic Data PrMounting Type: RACK
Alternating Current Voltage Rating in Volts: 100.0 and 240.0
Direct Current Voltage Rating in Volts: 24.0 and 60.0
0GX96
CISCO 2821-SEC/K9
CISCO2821SECK9
7025-01-565-9429Interface unit, Automatic Data PrSpecial Features: Device type-router; 2 RJ-45 ports; 4 expansion slots; 2 10/10/1000 mbps ports; RAM-256MB
III Part Name Assigned By Controlling Agency: Cisco 2821-SEC/K9 integrated services router
Power Source: External
0GX96
CISCO 2851 ROUTER
CISCO2851ROUTER
7025-01-534-9328Interface unit, Automatic Data PrSpecial Features: Dual gigabit ethenet integral services; ac power; 2 ge, 1 nme-xd, 1 evm, 4 hwic; 3 pvdm slots; 2 ahms and cisco ios ip base software
Frequency in Hertz: 47.0 and 63.0
Alternating Current Voltage Rating in Volts: 100.0 and 240.0
0GX96
CISCO 3560G-24PS
CISCO3560G24PS
7025-01-558-5763Interface unit, Automatic Data PrIII Part Name Assigned By Controlling Agency: Cicso catalyst 3560 series
0GX96
CISCO 3640
CISCO3640
7025-01-467-0547Interface unit, Automatic Data PrSpecial Features: Router contains 4 slots; 3.440 in. H., 17.500 in. W., 15.800 in. D.; rj 45 connector
Power Source: External
Frequency in Hertz: 47.0 and 63.0
0GX96
CISCO 3640A
CISCO3640A
7025-01-509-5116Interface unit, Automatic Data PrSpecial Features: Performance 50-70 kpps; rack unit height 2 ru; network module slots 4; default and maximum dram memory 32 mbup to 128 mb; default and maximum flash memory 16 mbup to 32 mb; power options ac, dc, rps
III Part Name Assigned By Controlling Agency: 4 slot modular router
0GX96
CISCO 3825-V/K9
CISCO3825VK9
7025-01-549-2988Interface unit, Automatic Data PrSpecial Features: Ac voltage auto-ranging; ac input input current 3.0 AMPS(110.0 volts); 2.0 AMPS(230.0 volts); dc voltage auto-ranging positive or negative; dc input current 12.0 AMPS(24.0 volts); 5.0 AMPS(60.0 volts); includes voice bundle; PVDM2-64; sp serv; memory 64MB compact flash; 256MB ddr sdram; operating temperature plus 32.0 to 104.0 degrees f; relative humidity 5.0 to 95.0 percent non-condensing
III Part Name Assigned By Controlling Agency: Cisco 3825 integrated services router
Power Source: External
0GX96
CISCO 3845 ROUTER
CISCO3845ROUTER
7025-01-534-9329Interface unit, Automatic Data PrSpecial Features: Integrated services; 2 gigabit ethernet fixed lan ports; one sfp slot, 4 nme, four hwic, 2 aim, 4 pvdm slots; cisco ip base software; ac power
Frequency in Hertz: 47.0 and 63.0
Alternating Current Voltage Rating in Volts: 100.0 and 240.0
0GX96

Listing A shows sample output from the show diag command on a Cisco 3845 router. The first example, a Cisco 3845 router, has four adaptors (in slots 0 to 3), which results in a great deal more. Page 9 of 13 Data Sheet C3845-NOVPN Cisco 3845 integrated services router with two Gigabit Ethernet fixed LAN ports, one SFP slot, four NMEs, four HWICs, two AIM slots, 4 PVDM slots Cisco IP Base software, and AC power Voice Bundles CISCO3825-V/K9 3825 Voice Bundle, PVDM2-64, SP Serv,128 MB Flash, 512 MB DRAM CISCO3825-SRST/K9 3825 Voice Bundle.

This post explains the interface numbering scheme used in Cisco 1800, Cisco 2800 and Cisco 3800 Series Routers. It also includes line numbering associated with async interfaces.

Existing router platforms (earlier than Cisco 1800, Cisco 2800, and Cisco 3800) contain a limitation. In some situations, such as when you insert WIC(s) out of order, the configuration of one WIC interface can be lost or applied to another WIC interface.

Example: Assume that you have a serial WIC-2T in WIC slot 1 and WIC slot 0 is empty. The interfaces are named serial 0/0 and serial 0/1. If you insert another WIC-2T into slot 0, the new WIC interfaces are named serial 0/0 and serial 0/1. The old WIC interfaces become serial 0/2 and serial 0/3. Therefore, the old WIC interface configuration moves to the new WIC interfaces.

Refer to How Async Lines are Numbered in Cisco 3600 Series Routers for more information.

In order to overcome this limitation, Cisco 1800, Cisco 2800, and Cisco3800 series platforms now have a three-tiered interface numbering format (slot/subslot/port) for interfaces on WIC slots only.

Note: The slot information for the Cisco 3800 series is the same as the 2800/1800 interface and line numbering. See New Interface and Line Number Conventions for information on interface and line numbering.

New Interface and Line Number Conventions

This section describes the new conventions for interface and line numbering.

  1. The interface numbering scheme is the same for async interfaces and non-async interfaces. To configure the line associated with an async interface, use the interface number to specify the async line.For example, line 0/0/0 specifies the line associated with interface serial 0/0/0 on a WIC-2A/S in slot 0. Similarly, line 0/1/1 specifies the line associated with interface async 0/1/1 on a WIC-2AM in slot 1.

    Note: This document uses the following words interchangeably:

    • Network-module-slot and slot.
    • Interface-card-slot and subslot.
  2. Ports on network modules are numbered like this:interface-number = network-module-slot/port

    OR

    interface-number = slot/port

  3. Ports on interface cards (such as WICs, VWICs and HWICs) installed directly in chassis slots is given here:interface-number = 0/interface-card-slot/port

    OR

    interface-number = 0/subslot/port

  4. This numbering convention is used for ports on interface cards that are installed in network module slots:interface-number = network-module-slot/interface-card-slot/port

    OR

    interface-number = slot/subslot/port

    Note: The slot/subslot/port format only applies to WIC interfaces. Interfaces that are native to the network modules still use only the slot/port format. That is:

    • <interface-name> slot/port is used whenever the interfaces are native on the network module.
    • <interface-name> slot/subslot/port is used whenever the interfaces are on the WIC slot of a network module (NM).
  5. Here is an example for numbering when the motherboard slot number is always 0. The native interfaces on the motherboard are numbered like this:
    • Fa0/0, Fa0/1 on Cisco 2811.
    • Gi0/0, and Gi0/1 on Cisco 2821 and Cisco 2851.

    The Motherboard WIC slots are numbered from 0 to 3. The number increments from right to left, and from bottom to top.

  6. Slot numbers for other slots increase from bottom to top, then right to left. Subslot numbers and port numbers within a slot also increase from bottom to top, then right to left.

Examples

Interfaces native to an extension network module (ENM):

If the ENM carries WIC cards, the WIC slot numbers start from 0:

The extension voice module (EVM) slot analog interfaces are numbered from voice-port 2/0/0 to voice-port 2/0/23, following the NM-HDA convention.

Interface Numbering

This section lists the interface numbering details for Cisco routers.

Table 1 – Interface Numbering on Cisco 1841

Figure 2 shows the interface numbering on Cisco 2851 platform with:

  • HWIC-1GE in WIC slot 0.
  • HWIC-4T in WIC slot 1.
  • WIC-1SHDSL in WIC slot 2.
  • VWIC-2MFT-T1 in WIC slot 3.
  • NMD-36ESW in ENM slot 1 and EVM-HD-8FXS/DID in EVM slot.

Figure 2 – Interface Numbering on Cisco 2851 Platform

Slots on Cisco 1841, 2801, 2811, 2821, 2851 Routers

This section illustrates the positions of the various slots on Cisco 1841, 2801, 2811, 2821, 2851 routers.

Figure 3 – Rear Panel of the Cisco 1841 Router

Ffxiv Duty Roulette Mentor List
  • Poker Sites No Deposit Free Bonus
  • Historic Central City Casino Parkway
  • Hindsgavl Slot Bryllup

  • Scroll to top